Anti-Buckling Plates to prEN2850 Annex C type B2 Test Piece
CP115011 | Anti-Buckling Plates to prEN2850 Annex C type B2 Test Piece
Mounts on CP114249 Base Support (Required not included)
With Strain-Gauge Cut-Outs
Max. Load : 100 kN (10,000 kgf, 22,000 lbf)
Temperature range : -100 to +350 °C (-148 to +662 °F)
附件身高 | 70 mm (2.75 in) |
---|---|
Accessory Weight | 0.3 kg (0.66 lb) |
Accessory Width | 36.5 mm (1.44 in) |
容量 | 100 kN (22,000 lbf) |
Lower Fitting | Requires platen 100 mm (4 in) or larger |
Temperature Rating | -100 to +350°C (-148 to +662°F) |
Testing Standards | ISO 14126 and prEN 2850 |
Upper Fitting | Requires platen 100 mm (4 in) or larger |
Composites Test Fixtures- Compression Anti-Buckling
The anti-buckling fixture was originally designed for rigid plastics per ASTM D 695, reinforced plastics per ASTM D 3846. It was also extended and used for high-modulus composites. Boeing then adapted the fixture so that it would be self supported between two platens to ensure consistent perpendicularity of the fixture. The SACMA standard followed the Boeing design with an added alternative support fixture with a cutout, which would allow bonded strain gages to be used at the center of the specimen for a more precise strain measurement.
- 产品
- 8/25/2014
- 0.5 MB