ASTM D623 Rubber Compression Flexing Fatigue and Heat Generation

An Introduction to ASTM D623 

ASTM D623 Rubber Compression Flexing Fatigue and Heat Generation 

Written by Rebecca Reiff-Musgrove

ASTM D623 contains test methods to compare the compressive fatigue characteristics and rate of heat generation of vulcanized rubbers. It describes two methods for applying a rapidly oscillating compressive stress under controlled conditions. Results include the measured temperature rise, degree of specimen dimensional changes and time to fatigue failure (in certain test conditions). In order to fully understand the test setups, procedures, and results requirements, it is important to review the full standard.

What is the test setup?

The test methods in ASTM D623 describe highly bespoke apparatuses, either the Goodrich Flexometer or the Firestone Flexometer, which apply a high-frequency, cyclic compression at a constant applied load. However, the standard Instron ElectroPuls® E3000 with WaveMatrix software and its Advanced Amplitude Control Module can achieve the same effect without the need for highly specialized equipment.

Instron can advise on appropriate accessories for testing at ambient and non-ambient temperatures.

ElectroPuls E3000 with Compression Platens
ASTM D623 Test Setup
ElectroPuls E3000 Test Instrument
5 kN Dynacell Dynamic Load Cell
Compression Platens
WaveMatrix Software with Advanced Amplitude Control Module

 

Typical Test

A typical test method in WaveMatrix using the ElectroPuls E3000 would be:

  1. Move the actuator in position control until a small contact force is measured.
  2. Ramp the actuator in load control to the required constant load (ASTM D623 Test Method A specifies loads of 160 N, 245 N, or 489 N).
  3. Hold at the static load for 5 seconds to allow the specimen material to relax.
  4. Apply the cyclic compressive oscillation in displacement control at the required amplitude and frequency (ASTM D623 Test Method A recommends strokes of 4.45 mm, 5.71 mm, or 6.35 mm, at 30 Hz). Use Advanced Amplitude Control to maintain the required constant mean force at a constant displacement amplitude.
Tips and Tricks

A key result from ASTM D623 is the temperature rise. WaveMatrix supports temperature measurement from a thermocouple transducer, allowing the temperature rise during the test to be recorded.

Instron provides chambers appropriate for testing at non-ambient temperatures, ASTM D623 recommended testing at 50°C or 100°C.

More precise displacement data can be gathered using a 2601 series LVDT (linear displacement transducer) attached to the platens.

If the applied loads are small in your application, more accurate data can be obtained using a smaller force cell. Instron supports dynamic force transducers down to 250 N.

Related Content

动态疲劳额定载荷传感器

2527 系列载荷传感器用于动态疲劳试验系统,有着卓越的性能,能够在传感器满量程的0.4% - 100% 范围内保证载荷示值的 ±0.5% 的载荷测量精度。自动传感器能够识别并进行电气校准,易于使用。载荷传感器可以确保在承受其载荷范围150%的负载时不会被损坏,在承受其载荷范围300%的负载时不会发生设备故障。所有 Instron 的载荷传感器都有单独的温度补偿,可以配置在符合国际标准的校准仪器上进行精度和可重复性测试,其测量误差不超过载荷传感器允许产生的误差的三分之一。

ElectroPuls® 手册

ElectroPuls 是一种先进的全电子材料试验机,用于各种材料和部件的动静态测试。ElectroPuls 系统采用单相电源供电,具有最新的材料试验技术,以及许多面向客户的其他功能。

2601 系列线性位移传感器

2601 系列线性位移传感器 (LVDT) 位移传感器用于衡量机架的位移。

WaveMatrix™3 Brochure

WaveMatrix3 is intelligent software designed for fatigue and dynamic testing of materials and components. It delivers flexibility - run everything from a simple static ramp, to cyclic waveforms through to complex multi-step, multi-axial tests The highly visual environment with integrated tabular screens, clear menu structures, time-based matrix test preview and configurable live test workspace is designed to be intuitive and instill confidence. Packed with intelligent features, such as data reduction and built-in project organization, designed to simplify your testing.